Monitoring N-able Cove Recovery Testing jobs

N-able Cove Data Protection Recovery Testing jobs typically run every 14 days instead of daily. By default, Backup Radar expects a result on every scheduled day, so these jobs can report a false No Result status (and generate tickets) on the days between tests.

This article explains how to monitor Cove Recovery Testing jobs on a biweekly cadence using either a template or a Backup Plan. Follow the section that matches how you activate and monitor backups in your account.

Who can use this feature?

  • Administrator users.

  • Standard users who have been granted access to templates or Backup Plans.

What you’ll need:

Note: The settings in this article assume your Recovery Testing jobs run every 14 days. If your Recovery Testing runs on a different cadence, adjust the No Result Threshold or Recovery Point Objective (RPO) to match.

Monitor Recovery Testing jobs with a template

Each template has two separate areas:

  • Rules determine which backups match the template.

  • Configuration determines the schedule, status calculation, and No Result Threshold applied to matching backups.

Create the template

  1. In Backup Radar, navigate to Manage > Templates.

  2. Click Add Template.

  3. Name the template (for example, Cove Recovery Testing), and click Add.

Configure the rules

In the Actions column, click Rules. Click Add Condition to add each of the following conditions:

Rule

Rule type

Comparison

Value

1

Backup Method

Is

MSP Backup API

2

Job Name

Contains

Recovery Testing

Make sure the conditions are joined with AND so both must match. Click Test to review the backups that match the rules, and click Save.

Configure the template settings

In the Actions column, click the Edit (blue pencil) icon to open the template configuration. Set the following values, and click Save.

Setting

Value

Schedules

Daily

Device Type

Match the device type used for the protected devices (for example, Unit for servers)

Status Calculation

Warning if mixed

No Result Threshold

14 days

The 14-day No Result Threshold displays days without a result as Pending instead of No Result, which covers the full window between Recovery Testing runs. For more details on each setting, see No Result Threshold and Status Calculation.

Activate the template and apply the changes

  1. In Manage > Templates, toggle the template to Active.

  2. Click Apply Changes.

  3. Review the Apply Templates summary, and click Apply.

Backup Radar applies the template to existing Recovery Testing backups that match the rules.

Important: If you have a broader Cove template (for example, one that only uses Backup Method = MSP Backup API), Recovery Testing jobs will match both templates and display as conflicts in the Apply Templates summary. Add a Job Name | Does not contain | Recovery Testing condition to the broader template, then apply the changes again.

Monitor Recovery Testing jobs with a Backup Plan

These steps cover only the settings specific to Cove Recovery Testing jobs. For a full walkthrough of every field, see Adding a Backup Plan.

  1. In Backup Radar, navigate to Manage > Backup Plans.

  2. Click Add Backup Plan.

  3. Configure each step using the values below.

Step 1: General Info

  • Plan name: Enter a name such as Cove Recovery Testing.

  • What results will this plan be ingesting?: Backups.

Step 2: Vendor & Classification

  • Backup Vendor: N-able.

  • Backup Application: Cove Data Protection.

  • Backup Source: API.

Leave Primary Backup selected under Classification.

Step 3: Additional Filters

Click Add Condition, and add the following condition:

Condition

Comparison

Value

Job Name

Contains

Recovery Testing

Click Test to confirm that only your Recovery Testing jobs are returned, and click Next.

Step 4: Schedule

  • Schedule interval: Expected to run every 1 day (the default).

  • Recovery Point Objective (RPO): Select RPO is, and set it to 15 days.

An RPO of 15 days allows for the job’s run time if a Recovery Testing job runs exactly 14 days after the previous one.

Step 5: Service Level Agreement

Because Recovery Testing jobs don’t run every day, compliance is based on the RPO only. When the RPO is longer than one day, Backup Radar disables the successful results within the SLA window and Last result is successful within the SLA window options.

  • Under SLA compliance criteria, select Recovery Point Objective is met. The summary below it displays RPO is 15 days.

  • Optionally, turn on SLA Compliance Ticket Creation to create a ticket when a Recovery Testing job falls out of compliance.

Step 6: Review

Review the plan settings, confirm Enable backup plan is turned on, and click Finish. See Adding a Backup Plan for details on each step.

Note: Backup Plans are applied in priority order, and new Backup Plans are the lowest priority by default. If you already have a Backup Plan for all Cove Data Protection backups, it will capture the Recovery Testing jobs first. Move the Recovery Testing plan above your broader Cove plan using the Edit Priority button on the Backup Plans list view page.

Confirm the configuration

Confirm that:

  • Only jobs with Recovery Testing in the job name are captured by the template or Backup Plan.

  • Recovery Testing jobs display as Pending (template) or in compliance (Backup Plan) on days between test runs, instead of No Result.

  • Your other Cove backups are still captured by their existing template or Backup Plan.

If Recovery Testing jobs still report as No Result after the next run, confirm the job’s actual cadence in Cove Data Protection and adjust the No Result Threshold or RPO to match.

🎙️ Interested in attending a live Q&A session with our Product Adoption team? Sign up to attend Backup Radar Office Hours and get real-time answers to your questions.

Any questions?

Reach out to our support team by submitting a request.

Submit a request

Was this article helpful?